Number of views:0

Functional Features

Voltage stabilization function: It can provide stable power output in situations such as power fluctuations, voltage dips, high voltage, surges, spike pulses, harmonic interference, etc., ensuring the normal operation of backend equipment.

Protection function: It has protection functions such as overvoltage, undervoltage, overload, short circuit, phase loss, and reverse phase (three-phase). When abnormal situations occur, it can quickly cut off the power supply and protect the safety of the equipment.

Bypass function: When UPS fails or requires maintenance, it can switch to bypass power supply without affecting the normal operation of backend equipment, and various protection functions are still effective in bypass state.

Intelligent monitoring: Some bypass cabinets are controlled by advanced digital signal processors (DSP), which have LCD screens to intuitively display the current voltage and current, real-time monitoring of power operation status, and have fault recording and storage functions. They also reserve RS485 communication interfaces for networking.

application area 

Widely used in the fields of power, petrochemicals, industrial and mining enterprises, data centers, new energy, etc., it provides protection and voltage stabilization functions for the front-end of large UPS uninterruptible power supplies, ensuring the long-term reliable operation of precision equipment in the back-end.

Technical Parameter

Capacity: Generally between 10KVA and 160KVA.

Input voltage: single-phase 220V, allowable fluctuation range is usually ± 15%.

Output voltage: single-phase 220V, with a voltage stabilization accuracy of ± 1%.

Frequency: 50Hz/60Hz, allowable fluctuation range ± 5%.

Efficiency: The overall output efficiency of the machine is ≥ 98%.

Reaction time: generally less than 100ms.

Composition structure

It mainly consists of isolation transformer, compensation transformer, voltage regulating transformer, transmission mechanism, brush contact system, control system, bypass maintenance system, DC check diode (optional), transmitter (optional), etc.

precautions

Selection and matching: Based on the actual power, voltage, frequency, and other requirements of the load, select a bypass cabinet with appropriate capacity and parameters to ensure stable and reliable power supply to the load.

Installation environment: The bypass cabinet should be installed in a dry, ventilated, and non corrosive gas environment, avoiding direct sunlight and humid conditions, while ensuring the stability and safety of the installation location.

Maintenance: Regularly maintain the bypass cabinet, check the operating status of each component, clean dust and debris, and ensure that its performance is always in good condition.